22 Lý Tự Trọng, Minh Khai, Hồng Bàng, Hải Phòng.

itvc.haiphong@itvc-global.com

Đồng hồ vạn năng KYORITSU 1061, K1061 (True RMS)

(Click vào để xem ảnh lớn)

Đồng hồ vạn năng KYORITSU 1061, K1061 (True RMS)

Giá: Liên hệ Lượt xem: 0 Hàng mới

Đồng hồ vạn năng KYORITSU 1061, K1061 có các thông số kỹ thuật sau:

Chế độ : True RMS

DC V : 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V

AC V : [RMS] 50.000/500.00mV/5.0000/50.000/500.00/1000.0V

DCV+ACV : 5.0000/50.000/500.00/1000.0V

DC A : 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A

AC A[RMS]  :500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A         

DCA+ACA  : 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A         

Ω : 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ         

Continuity buzzer     : 500.0Ω     

Diode test : 2.4V                

C: 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF

F: 2.000~9.999/9.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz

Nhiệt độ : -200~1372ºC (K-type )         

Chức năng khác : Data Hold (D/H), Auto Hold (A/H), Peak Hold * (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight         

Nguồn : R6P (1.5V)×4        

Kích thước : 192(L)×90(W)×49(D) mm         

Cân nặng     : 560g     

Nguồn :      LR44 (1.5V) × 2

Kích thước :192(L)×90(W)×49(D) mm

Khối lượng : 560g 

Phụ kiện : Vỏ, Pin, HDSD

Bảo hành : 12 tháng

Hãng sản xuất : Kyoritsu - Nhật

Xuất xứ : Nhật

Chi tiết sản phẩm

High Accuracy, High Performance and Reliable Measurements
0.02% basic DC accuracy
Large display with 50,000 counts
Dual display for double indication for AC and DC, V and Hz, etc.
True-RMS Measurements AC and AC+DC
Wide AC Frequency bandwidth from 10Hz to 100kHz *
True-RMS or MEAN value detection mode can be selected *
Fast Peak Hold response time of 250µs
Low-pass filter for motor drive measurements *
Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current *
User calibration function
* Only for KEW 1062

1061/1062
CE
(Photo: 1062)
Safety design for industrial use
Complies with IEC 61010-1 CAT.III 1000V, CAT.IV 600V
Terminal shutter to prevent incorrect test leads is insertion in current terminals
Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
Large data internal memory
  KEW 1062: 10,000 data (logging), 100 data (manual)
  KEW 1061: 1,000 data (logging), 100 data (manual)
Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)

TRUE RMS CAT.IV 600V
 
KEW 1061 KEW 1062
Detection mode RMS MEAN/RMS (switch)
DC V 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V
(Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V])

|±0.02%rdg±2dgt (Basic accuracy)
AC V
[RMS]
50.000/500.00mV/5.0000/50.000/500.00/1000.0V
(Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V])
|±0.7%rdg±30dgt (Basic accuracy) |±0.4%rdg±30dgt (Basic accuracy)
AC V
[MEAN] *
-- 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V
(Input impedance:
11MΩ<50pF [50/500mV/5V],
10MΩ<50pF [50/500/1000V])


|±1%rdg±30dgt (Basic accuracy)
DCV+ACV 5.0000/50.000/500.00/1000.0V
(Input impedance: 11MΩ<50pF [5V], 10MΩ<50pF [50/500/1000V])
|±1%rdg±10dgt (Basic accuracy) |±0.5%rdg±10dgt (Basic accuracy)
DC A 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A

|±0.2%rdg±5dgt (Basic accuracy)
AC A
[RMS]
500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
|±1%rdg±20dgt (Basic accuracy) |±0.75%rdg±20dgt
|(Basic accuracy)
AC A
[MEAN] *
-- 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A

|±1.5%rdg±20dgt (Basic accuracy)
DCA+ACA 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
|±1.5%rdg±10dgt (Basic accuracy) |±1%rdg±10dgt (Basic accuracy)
Ω 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ