22 Lý Tự Trọng, Minh Khai, Hồng Bàng, Hải Phòng.
itvc.haiphong@itvc-global.com
Chi tiết sản phẩm
Hãng sản xuất: Fluke
Model: Fluke 3130-G2M
Bảo hành: 12 tháng
Giải áp suất (bơm bên trong): -80 kPa đến 2 MPa (-12 đến 300 psi, -0.8 đến 20 bar)
Giải áp suất (không khí từ ngoài vào) : 0 đến 2 MPa (0 đến 300 psi, 0 đến 20 bar)
mA: 0 đến24.000 mA
Volts:0 đến 30.000 V dc
Đơn vị: psi, bar, mbar, kPa, MPa, kgf/cm2, mmH2O @ 4 °C, mmH2O @ 20 °C, cmH2O @ 4 °C, cmH2O @ 20 °C, inH2O @ 4 °C, inH2O @ 20 °C, inH2O @ 60 °F, mmHg, @ 0 °C, inHg @ 0 °C
Nguồn: adapter 12 V dc (Universal ac adapter/charger supplied)
Pin: pin sạc trong 3800 mAh
Kích thước: 15.25 in L x 12 in W x 7 in D
Trọng lượng: ~7 kg (15 lb)
Phụ kiện gồm: vở đựng, bộ sạc, pin sạc, dây đo, HDSD
The 3130 Portable Pneumatic Pressure Calibrator is ideal for calibrating pressure transmitters, transducers, gauges and similar devices. The 3130 contains everything you need to generate, control and measure pressure, as well as read the output of the device under test (DUT).
The internal, motorized pump provides an easy, efficient alternative to time consuming, tiring hand pumps. For applications that involve filling a large volume with pressure, the 3130 allows for connection to an external gas supply such as compressed plant air. The pressure can be fine-tuned using the variable volume.
The 3130 offers an onboard pressure sensor with a full scale of 2 MPa (300 psi, 20 bar) and an accuracy of ± 0.025 % reading + 0.01 % FS (includes precision, one-year stability, uncertainty of the calibration standard, and temperature effects). In addition, the 3130 can be used with the Fluke 700P pressure module series to improve measurement performance across the entire range.
The 3130 offers electrical measurement capabilities for calibrating pressure transducers and transmitters, including measurements of 4 to 20 mA or 0 to 30 V dc. In addition, the 3130 provides 24 V dc supply to power the device under test and can generate current in the 4 to 20 mA range.
The 3130 is built into a ruggedized case with internal storage for power supply, test leads, and fittings. In addition, it includes a rechargeable, NiMH battery, allowing for approximately 50 hours of operation. When using the internal pump, the battery is sufficient to provide up to 100 calibration cycles to 300 psi. The battery is recharged by simply plugging the unit in using the included universal mains adapter.
Environmental |
|
Operating temperature | -10 °C to +50 °C |
Storage temperature | -20 °C to +60 °C |
Power requirements | 12 V dc (Universal ac adapter/charger supplied) |
Battery | Internal 3800 mAh advanced NiMH pack |
Operating time |
|
On full charge |
Approx 50 hours (Measure only or external air; no pump) |
Using internal pump | Approx 100 calibration cycles to 300 psi |
Physical |
|
Dimensions | 15.25 in L x 12 in W x 7 in D |
Weight | ~7 kg (15 lb) |
EMI/RFI conformance | EN61326:2006 Annex A |
Connectors/ports | 1/8 in NPT (External supply port and test port) |
Included accessories |
Manual, NIST-traceable certificate, test leads, universal ac adapter/charger |
Ranges |
|
Pressure (internal pump) | -80 kPa to 2 MPa (-12 to 300 psi, -0.8 to 20 bar) |
Pressure (external air) | 0 to 2 MPa (0 to 300 psi, 0 to 20 bar) |
mA | 0 to 24.000 mA |
Volts | 0 to 30.000 V dc |
Engineering units |
psi, bar, mbar, kPa, MPa, kgf/cm2, mmH2O @ 4 °C, mmH2O @ 20 °C, cmH2O @ 4 °C, cmH2O @ 20 °C, inH2O @ 4 °C, inH2O @ 20 °C, inH2O @ 60 °F, mmHg @ 0 °C, inHg @ 0 °C |
Instrumental measurement uncertainty |
|
Pressure | 0.025 % of reading ± 0.01 % FS |
mA | 0.015 % of reading ± 0.002 mA |
Volts | 0.015 % of reading ± 0.002 V |
Temperature effect (all functions) |
|
No effect on accuracy on all functions from 15 °C to 35 °C | |
Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C |
Option
Accessory |
Description |
750Pxx |
Pressure Module Series |