Palm-sized with a built-in probe type, a key -lock function
Applications
Eddy current
· Substrate: Non-magnetic metal (aluminum, copper, austenitic stainless steel, etc.)
· Coating: Non-conductive coating (painting, resin, anodized coating, etc.)
Specifications
Measuring range : 0~900μm
Resolution : 1μm
Accuracy : ±1μm to a flat level or ±3% the indicated value
Display method : LCD digital, with a display-hold
Probe : one point contact constant pressure type with V-groove (built-in)
Min. measurable area : φ18
Power : Dry batteries (R03 1.5V)×2, auto-power off
Temperature : 0~40℃(non-condensing)
Weight and Dimensions : 56(W)×109(H)×34(D) mm, 140g
Additional function : 0.1μm unit by switching (below 100μm)
Accessories : thickness standards, zero plates for test